The CVQ valve is operated by the EKC controller. Please notice that a power failure will cause the CVQ pilot valve to fully open ICS / PM. If it is required that. Type Code, EKC Weight, Kg. Approval, CE, C-TICK, EAC, LLC CDC TYSK. Data comm. options, LON RS EAN no. Freq. View and Download Danfoss EKC user manual online. Controller for regulation of media temperature. EKC Controller pdf manual download.

Author: Akinotilar Faelrajas
Country: Azerbaijan
Language: English (Spanish)
Genre: Relationship
Published (Last): 15 May 2017
Pages: 280
PDF File Size: 1.58 Mb
ePub File Size: 14.91 Mb
ISBN: 133-7-71719-615-8
Downloads: 88877
Price: Free* [*Free Regsitration Required]
Uploader: Zutaxe

Precise refrigeration and air conditioning is essential for many applications and demand is constantly increasing. Here it is important to eliminate even danfosss smallest temperature changes so that the measuring results are not affected. However, applications in the food industry are also possible. In applications such as this, constant nozzle air temperature from evaporators xanfoss the key to success.

This can be easily achieved with electronic suction throttle regulation or media temperature control. In the case of a media temperature control for refrigerating plants with a pipe size of up to 54 mm, an electrically controlled valve e.

B – Product specifications

This valve is equipped with a stepper motor and is controlled by an electronic controller e. A fast-reacting temperature sensor e. This sensor measures the actual value of the outlet air temperature of the evaporator and feeds this back to the controller. The controller now compares its temperature set point with the actual value and decides whether the stepper motor valve should be opened further or closed. A completely open valve ensures maximum refrigeration and therefore the lowest possible outlet temperature in the actual load situation.

A valve that is almost closed creates a high outlet temperature. Therefore, the control gives the valve the command “open valve” in situations where the reference value is far lower than the actual value.

Even with a temperature difference of just 1 K, the control forces a small opening to prevent the control from overshooting the set point. Special attention must be paid to the start-up phase of regulation. The “EKC ” control has three different transient processes available. The first option is the fastest possible refrigeration. In the case of this setting, a very clear undershooting of the outlet temperature of the evaporator is to be expected to facilitate fast refrigeration and ensure the reference temperature is quickly achieved.

The second option only allows slight undershooting. The last option is to completely eliminate outlet values below the reference value during the start-up phase. The advantage of this is very gentle cooling of unpackaged goods, in which any unnecessary dehumidification is avoided.

However, in this case, more time must be planned for achieving the required reference value. The controller is operated using two push buttons. The controller can be completely programmed using these two daanfoss combined with a three-digit display where all important data danfos displayed.

This means that any fitter at the plant can intervene in the control circuit and view relevant data. In the control menu, not only are basic adjustable values displayed, but it is also possible to precisely influence certain events by adjusting stability and danflss factors.

  CENMAX HIT 320 PDF

The service menu of the electronic controller is of particular interest to the fitter upon commissioning or servicing of the plant. All parameter values that begin with “u” display actual plant values which are important for all types of troubleshooting and for evaluating the state of the plant. These values provide information about the state of the plant. On the one hand, they can be read quickly, which saves the effort of measuring with the temperature gauge.

And on the other hand, you can see immediately which values the control takes for granted. It is therefore standard procedure for an experienced fitter to check the control sensor and, if necessary, the defrost sensor in electronic systems before the actual commissioning this is very easy to do for standard resistance sensors using an Ohm measuring device.

This procedure can be avoided by looking at the service menu; here it can be seen immediately in case of doubt, double check with the thermometer whether the value is realistic.

The “KVS” is a continuous valve with which even the smallest fluctuations in evaporation pressure can be avoided. P control involves standard regulation according to the deviation example: In the case of PI regulation, the “reset time” I component can be changed individually, which simultaneously leads to the adaptation of the reaction speed of control.

DANFOSS EKC USER MANUAL Pdf Download.

Either can be necessary. The “D component” in PID control also optimises the control characteristics in the case of a sudden change to the reference value. This control mode is particularly advisable if the system is operated with external reference value changes, e.

Refrigeration specialists know that the topic of “humidity” plays an important role in refrigeration, especially where unpackaged goods, meat, vegetables and fruit are concerned.

However, there can also be situations in refrigeration plants where humidity is required. For this purpose, indirect measures are normally taken, such as changing the evaporator fan levels or the evaporator speed i. This point can be directly influenced with an electronic suction throttle system: Of course, it is also the case here that the dew point for dehumidification must always be undershot.

It is always easy to readjust a system like this through the eliminated condensate quantity at the evaporator. A system like this is suitable for ventilation and comfort air conditioning plants and conditioning cabinets, as well as for fruit and vegetable storage.

The “EKC ” also offers the option of defrosting regulation by external initiation through an danfooss contact. After defrosting has been initiated, its standard procedure must be defined by setting the control appropriately.

In the case of hot gas defrosting, the “KVS” valve closes during the defrosting procedure. After defrosting, the “KVS” valve does not open abruptly – somewhat like a standard solenoid valve.

This is an advantage, particularly dangoss the release of high pressure and, if necessary, liquid in the evaporator are concerned. Danflss, it is not necessary to fit an additional danfosa in the sanfoss line since the “KVS” can also be used for this shut-off function.

  CENTER AXIS RELOCK CAR PDF

Precise media temperature control

In the case of electric defrosting, the “KVS” is opened. A defrost sensor in the evaporator package ends the defrosting process as soon as the temperature of the evaporator package vanfoss reached the temperature to which the sensor is set. For safety, rkc maximum defrost duration can also be set in the refrigeration controller, which ends the defrosting process in the case of a defective defrost sensor or a similar fault.

After defrosting, the drip-off time begins. Once these processes have dsnfoss, the refrigeration process is restarted. In simple terms, the purpose of the drip-off time is to drain off ice that has turned into water on the evaporator via the condensate drain. If connection sizes larger than 54 mm are required for the suction line, it is recommended that you implement a solution with a main valve.

Here, the main valve with pilot is also fitted in the suction line. However, with “CVQ” an actuator is used to operate the valve instead of a stepper motor.

This heating closes and opens the valve. The “NTC” resistor sends the control confirmation of the degree of opening of the valve via the inner actuator temperature. The actual value of this actuator temperature and the current reference value can be read in the control menu of “EKC ” “”. This is a good troubleshooting aid. Remote service is also possible for this control system.

It is possible to equip the control with a LON module and record the appropriate data damfoss a master unit and to intervene in the control system remotely using a modem connection.

This can be done using special software type “Danfoss AKM”. This means that this media temperature control can be integrated in complex Danfoss control system networks. Home page Service and support Case studies Precise media temperature control. Precise media temperature control. Suction dsnfoss installation In the case of a media temperature control for refrigerating plants with a pipe size of up to 54 mm, an electrically controlled valve e.

Different transient processes in the start-up phase Special attention must be paid to the start-up phase of regulation. Operation The controller is operated using two push buttons. Service The service menu of the electronic controller is of particular interest to the fitter upon commissioning or servicing of the plant. Continuous electronic valves The “KVS” is a continuous valve with which even the smallest fluctuations in evaporation pressure can be avoided.

Defrosting The “EKC ” also offers danfosx option of defrosting regulation by external initiation through an input contact. Solution for large plants If connection sizes larger than 54 mm are required for the suction line, it is recommended that you implement a solution with a main valve.